EMC/EMI/ESD Standards for Lamps and Luminaires

dBi Corporation


A2LA Accredited Laboratory
Certificate Number 1985-01

John R. Barnes KS4GL, PE, NCE, NCT, ESDC Eng, ESDC Tech, PSE, SM IEEE
December 19, 2010
jrbarnes@iglou.com

Lamps and luminaires (floodlights) provide illumination. If they are unintentional radiators, most nations require them to meet:

The European Union (EU) also requires them to meet:

Australia and New Zealand also require them to meet:

Thus, to be sold worldwide, (unintentional radiator) lamps and luminaires must meet:

Combining all of these requirements:

If the highest clock/ switching frequency is above 1.705MHz, Radiated Emissions must be measured from (FCC Part 15-2008 Paragraph 15.33(b)(1)):

Radiated Emissions limits are:

Radiated Emissions from 9kHz to 30MHz are measured with a loop antenna. with the limits in EN 55015 (AS/NZS CISPR 15) Table 3 or 3a.

Conducted Emissions on AC plugs must be measured from 9kHz-30MHz, with the limits:

Conducted Emissions on load terminals must be measured from 150kHz-30MHz, with the limits:

Conducted Emissions on control terminals must be measured from 150kHz-30MHz, with the limits:

Insertion loss between a fluorescent lamp and the power source must be measured from 150kHz-1.605MHz, with limits (EN 55015 & AS/NZS CISPR 15 Table 1):

Personal computers, personal computer monitors, and television sets, with a rated power <=600W, must meet the EN 61000-3-2 (AS/NZS 61000.3.2) Class D (Table 3) Harmonics limits. Lighting equipment must meet the Class C (Table 2) Harmonics limits. Portable tools and non-professional arc-welding equipment must meet the Class B (1.5 times Table 1) Harmonics limits. All other products must meet Class A (Table 1) Harmonics limits. Section 7 exempts certain products from these Harmonics requirements:

Products that are unlikely to produce significant voltage fluctuations, or flicker, do not have to be tested for Flicker (EN 61000.3.2 Section 6,1). Otherwise ITE products must be tested to EN 61000-3-3 (AS/NZS 61000.3.3).

These products must meet EN 61000-4-2 (AS/NZS 61000.4.2) to Performance Criterion B for Electrostatic Discharge (ESD) up to:

Indirect discharges to the horizontal coupling plane and vertical coupling plane only have to be tested at +/-4kV. Contact and air discharges to the product must be tested at the limit voltages and at intermediate voltages.

These products must meet EN 61000-4-3 (AS/NZS 61000.4.3) to performance criterion A for radiated electromagnetic fields with 80% amplitude modulation at 1kHz, at 3V/m for 80-1000MHz.

These products must meet EN 61000-4-4 (AS/NZS 61000.4.4) to performance criterion B for Electrical Fast Transient/Bursts (EFTB) at 5kHz, at

These products must meet EN 61000-4-5 (AS/NZS 61000.4.5) to performance criterion B for Surges, at +/-1kV line-to-earth and +/-0.5kV line-to-line on AC inputs, or +/-2kV line-to-earth and +/-1kV line-to-line on AC inputs (see EN 61547 Table 10).

For surge tests, the product must be tested at the limit voltages and at intermediate voltages.

These products must meet EN 61000-4-6 (AS/NZS 61000.4.6) to performance criterion A for Conducted Immunity with 80% amplitude modulation at 1kHz, for 150KHz-80MHz, at:

If these products contain components that are susceptible to magnetic fields, they must meet EN 61000-4-8 (AS/NZS 61000.4.8) to performance criterion A for 3A/m magnetic fields at the AC mains frequency of 50Hz or 60Hz.

These products must meet EN 61000-4-11 (AS/NZS 61000.4.11) for Voltage Dips on AC voltage inputs to:

DISCLAIMER
These web pages are freely offered to anyone who wishes to use them. No warranty for their use is expressed or implied. The most-current versions may be downloaded from the our web site at http://www.dbicorporation.com/.

These web pages can point you to regulations and standards applying to your product(s), but please refer to the regulations and standards themselves when deciding how to test your product(s). A regulation's or standard's title gives you strong clues as to what it covers, but its scope (usually section 1) tells you for sure. Carefully check the footnotes in tables, to see if your product falls into an exception that lets you avoid unnecessary tests (or sometimes requires additional special testing). Exceptions that can help you also sometimes hide in the Test Setup section (usually section 7). Also check the Test Report section (usually section 10) for any special documentation required.

COMMENTS
If you refer to one or more of these documents in written communications, please attribute them to http://www.dbicorporation.com/. Similarly, if you link to them from your own web page(s), we would appreciate an E-mail to jrbarnes@iglou.com giving the universal resource link (URL) so that we may provide a reciprocal link.

Please send critiques, corrections, and/or additions to jrbarnes@iglou.com , or by snailmail to:
John Barnes
dBi Corporation
216 Hillsboro Ave
Lexington, KY 40511-2105


dBi Corporation is an A2LA-accredited EMC/EMI/ESD testing laboratory (test house) based in Lexington, Kentucky. In the last nine years we have done the FCC-/ CE-Marking-approval EMC/ EMI/ ESD tests for over 308 products developed by clients-- bringing over 97% of them into compliance with both domestic and international laws and standards. We have also served as an expert witness on electronics in three lawsuits. Before joining dBi, our staff was directly involved in putting over 115 major electronic products into mass production at Sycor, IBM, and Lexmark. Our staff has over 37 years experience in the computer and electronics industries, developing electronic products and electronic equipment that:
  1. Work.
  2. Are safe and reliable.
  3. Can be manufactured, tested, repaired, and serviced economically.
  4. May be sold and used worldwide.
  5. Can be easily adapted/enhanced to meet new and changing requirements.

Our President, John R. Barnes, is a Professional Engineer (PE) licensed in the state of Kentucky, a NARTE-Certified Electromagnetic Compatibility Engineer (NCE), a NARTE-Certified Electromagnetic Compatibility Technician (NCT), a NARTE-Certified Electrostatic Discharge Control Engineer (ESDC Eng), a NARTE-Certified Electrostatic Discharge Control Technician (ESDC Tech), a NARTE-Certified Product Safety Engineer (PSE), a Senior Member of the IEEE (SM IEEE), and an Advanced-class amateur radio operator. He has written three books: Electronic System Design: Interference and Noise Control Techniques, which was published in English in 1987 and in Russian in 1990; and Robust Electronic Design Reference Book, Volumes I and II, which came out in 2004. John has also written articles on designing electronics for electrostatic discharge (ESD) immunity for Printed Circuit Design and Conformity magazines.

dBi Corporation can be contacted by:

Go to Main Web Site Index Go to Full Standards Index Go to ITE Standards Index Go to Residential/ Commercial Standards Index Go to Industrial Standards Index
Go to Lab Equipment Standards Index Go to Audio/ Video Equipment Standards Index Go to Lamps/ Luminaires Standards Index Go to Appliance Standards Index
Last revised December 19, 2010.